Baoding Zhongyi Electric Corporation is one of the leading manufacturers and suppliers of 1250kva transformer in China, featured by quality products and good price. Please rest assured to buy advanced 1250kva transformer for sale here from our factory.
A 1,250 kVA transformer is the size that turns up in the middle of a project: too big for the packaged substation the electrical contractor quoted, too small to justify a 33 kV switchroom of its own. It is also one of the few ratings where the standard preferred number is genuinely the right answer. 1,250 kVA is a 25 % step above 1,000 kVA, and the next size up, 1,600 kVA, is 28 % larger - which is why this rating sits behind so many 11 kV industrial feeders.
The 1250KVA Transformer on this page is a three-phase, oil-immersed unit built at our works in Baoding, Hebei, for an 11 kV primary and a 400 V secondary. It is the build most often specified for plant distribution, pumping stations, small industrial estates and commercial buildings where the incoming supply is already 11 kV.

Oil-immersed units in the assembly bay before dispatch
Ratings and currents
|
Rated power |
1,250 kVA |
|
Primary voltage |
11 kV |
|
Secondary voltage |
400 V |
|
Primary current |
65.6 A |
|
Secondary current |
1,804.3 A |
|
Frequency |
50 / 60 Hz |
|
Phase |
Three phase |
|
Cooling |
ONAN (oil natural, air natural) |
|
Oil mass |
470 kg |
|
Total mass |
2,750 kg |
|
Overall dimensions |
1,790 × 1,330 × 1,630 mm |
|
Ambient temperature |
−25 °C to +55 °C |
|
Installation altitude |
≤ 1,000 m |
Currents are calculated at rated power and rated voltage: I = S / (√3 × V). The 65.6 A primary figure matters less than people expect - the cable and switchgear on the 11 kV side are sized by fault level, not by load current. The 1,804 A secondary figure is the one that drives cost, and it moves with your secondary voltage: 415 V brings it down to 1,739 A, and 433 V down to 1,667 A. If your plant is specified at 415 V, say so before we quote, because the difference decides your busbar size and your main breaker frame.
Impedance: settle this before you buy switchgear
Units at this rating and voltage class are normally designed in the 4.5 % to 6 % impedance band. Read that as a design range, not a fixed specification: the figure for your unit is fixed when the outline drawing is approved, and it is then confirmed by the impedance-voltage measurement on the routine test report. It is worth settling early, because the two ends of that band are not close together.
At the rated 1,804 A secondary current, 6 % impedance puts roughly 30 kA through the 400 V busbar under a solid short circuit. Design the same unit at 4.5 % and the same busbar sees about 40 kA. That is the difference between a 36 kA and a 50 kA breaker frame, a heavier busbar bracing requirement, and often a different switchgear package altogether. If your LV board is already ordered, give us its breaking capacity and we will design the impedance to sit inside it rather than quoting a default.
Oil, weight and footprint, in site terms
470 kg of oil and 2,750 kg all-up keeps this unit inside what a small crane or a heavy forklift can handle, but those numbers need to reach the site team before the plinth is poured. Overall dimensions are 1,790 × 1,330 × 1,630 mm. Keep the oil mass separate from the total in your planning - it is the figure your bund is sized against, and the figure any top-up at site is based on.
Three things that catch people out. A 2,750 kg unit needs a plinth rated for the load during lifting, not just the static load it settles at. Confirm what the 1,630 mm height includes - tank only, or tank plus bushings and conservator - before you fix the ceiling height of a substation room. And the −25 °C to +55 °C ambient range covers most of the Middle East, Africa and South-East Asia without derating, but the 1,000 m altitude limit does not: above that, loading has to be corrected under IEC 60076-2, and it is far cheaper to correct it on the drawing than on site.
1,250 kVA, or the next size up?
Our rule of thumb is to size for a continuous load of 60 % to 75 % of nameplate, so that a cooling fault or a single outage does not take the plant down. On 1,250 kVA that works out at a peak demand of roughly 750 to 940 kVA. If your peak already sits near the top of that band and you expect growth, going straight to 1,600 kVA usually costs less over ten years than replacing a 1,250 kVA unit in three. Send the load list and we will tell you which side of that line you are on - it is a five-minute answer for us and an expensive one to get wrong.
Where it can be installed
Oil-immersed construction is cheaper per kVA than a dry-type unit at this rating, quieter in most designs, repairable on site by your own maintenance team, and considerably more forgiving of sustained overload. What it needs in return is containment: a bunded plinth, oil retention, and fire separation from occupied buildings. That normally rules it out of a shopping centre basement, a tunnel or a hospital plant room, where a cast-resin unit is the right answer instead.
For an outdoor yard, a dedicated substation room or a kiosk, this is the build to specify. If you are not sure which way your site has to go, tell us the room dimensions and what is above and below it, and we will say plainly whether this unit fits the space.
Manufacturing, testing and packing
Our site covers 33,300 m² with 260 employees and an annual capacity above 1,000 MVA. Eighteen engineers handle design and type-test work. Cores are step-lapped from cold-rolled grain-oriented silicon steel, windings are copper and vacuum-dried before oil filling, and every tank is welded, pressure-tested, filled and leak-tested before it leaves the bay.

Coil winding, vacuum drying and high-voltage testing, all in-house
Every 1250KVA Transformer ships with a routine test report to IEC 60076-1: winding resistance, ratio and vector group, no-load loss and no-load current, impedance voltage and load loss, applied voltage and induced voltage. Lightning impulse, temperature rise, short-circuit and noise measurements are available as type tests, with third-party witnessing if your contract requires it. ISO 9001:2015 covers the process, and CE, UL and RoHS documentation is issued on request.

Quality management, CE conformity and product certification held by the works
MOQ is one unit. Standard export packing is a seaworthy wooden crate with the transformer braced to the base plate; pallets and rack frames are available where the site has a crane limit. Lead time is quoted per order - for a standard rating on an existing design it is measured in weeks, not months. Warranty is 24 months, and OEM and ODM are available including your nameplate, your drawing numbers and your test report format.

Export packing: braced to the base, then closed in a seaworthy case
FAQ
How many amps is a 1250 kVA transformer?
On an 11 kV / 400 V build, 65.6 A on the primary and 1,804.3 A on the secondary. At 415 V secondary the LV current falls to 1,739 A, and at 433 V to 1,667 A. The LV figure is the one that sizes your busbar, so fix the secondary voltage before the switchgear is ordered.
How much does a 1250 kVA transformer weigh?
2,750 kg all-up, of which 470 kg is oil. The oil mass is the number your bund and any site top-up are based on, and it is listed separately from the total for exactly that reason. Final figures are confirmed on the approved outline drawing for your build.
What fault level will it put on my LV board?
Between roughly 30 kA and 40 kA at the 400 V busbar, depending on where the impedance is set in the 4.5 % to 6 % design range. Tell us the breaking capacity of your board and we will design to it.
Should I order 1,250 kVA or 1,600 kVA?
If your continuous peak sits between 750 and 940 kVA with no growth planned, 1,250 kVA is the right size. If your peak is already at the top of that band, or you have expansion on the drawing board, price the 1,600 kVA unit as well - over ten years it is usually the cheaper answer. We publish specifications for a 2,000 kVA oil-filled unit if you want to see what the next classes look like.
Can it be installed indoors?
Yes, in a dedicated substation room. The room still needs oil containment and fire separation under your local code, and the 470 kg of oil is what the bund has to hold. If containment is impossible, a cast-resin unit is the correct choice and we build those in the same works.
Get a priced offer
A 1250KVA Transformer is quoted against your fault level, your secondary voltage and your load profile, not against a list price. Send us those three, even as rough numbers, plus your site ambient and altitude, and you will get a priced offer together with a preliminary outline drawing. If you are still weighing oil-immersed against dry-type, or 1,250 kVA against 1,600 kVA, say so - we will tell you which one suits your site rather than which one is easier for us to build.
Baoding Zhongyi Electric Corporation · MOQ 1 unit · 24-month warranty · 7×24 technical support · Send your specification and we will come back with a price
Hot Tags: 1250kva transformer, China, suppliers, manufacturers, factory, buy, price, for sale, 315 kva pole mounted transformer, 3 phase 50 kva transformer, transformer 315 kva, 20mva transformer, 1000 kva 11kv 433v transformer, 250 kva transformer
You Might Also Like
Learn More1500 KVA 3 Phase Power Distribution Transformer
Learn More33 KV Transformer
Learn More2.5 MVA Oil Immersed Electrical Distribution Transfo...
Learn MoreSingle Phase Overhead Pole Mounted Distribution Tran...
Learn MoreCooper Oil Filled Pad Mounted Distribution Transformers
Learn MoreIndoor Oil Type Electrical Transformer
Send Inquiry