Products

2MVA Transformer
video
2MVA Transformer

2MVA Transformer

Power: 2MVA
Primary Voltage: 10kV/11KV/22KV/33KV
Secondary Voltage: 400V/690V
Frequency: 50/60Hz
Connection: Yyn0 or Dyn11
Warranty: 2-years

Features

Baoding Zhongyi Electric Corporation is one of the leading manufacturers and suppliers of 2mva transformer in China, featured by quality products and good price. Please rest assured to buy advanced 2mva transformer for sale here from our factory.

 

2,000 kVA is the point where a transformer stops being an off-the-shelf item. Below this rating, most buyers compare two data sheets and take the cheaper one. At 2 MVA the numbers on that sheet start interacting with each other: impedance sets the fault current your switchgear has to survive, the cooling class decides how much overload you can carry through a hot afternoon, and losses sit on the electricity bill for the next 25 years.

We build the 2MVA Transformer in both oil-immersed and cast-resin versions at our works in Baoding, Hebei. Most of them go to utilities, EPC contractors and industrial plants against a project specification rather than a catalogue number.

2MVA transformer oil-immersed units in the assembly bay
Oil-immersed units on the shop floor before dispatch

Standard ratings and currents

Configuration

Primary

Secondary

Primary current

Secondary current

Cooling

Oil-immersed

10 kV

400 V / 690 V

115 A

2,887 A / 1,673 A

ONAN

Oil-immersed

11 kV

415 V

105 A

2,782 A

ONAN

Oil-immersed

22 kV

415 V

52.5 A

2,782 A

ONAN / ONAF

Oil-immersed

33 kV

11 kV

35 A

105 A

ONAN

Cast resin (dry)

11 kV

415 V

105 A

2,782 A

AN / AF

Cast resin (dry)

22 kV

433 V

52.5 A

2,667 A

AN / AF

Currents are calculated at rated voltage: I = S / (√3 × V). Move the secondary from 415 V down to 400 V and the LV current rises to roughly 2,887 A, which is often enough to push you into the next busbar size. Tell us your actual secondary voltage before we quote.

2MVA transformer outline drawing and overall dimensions
Outline drawing, 2000 kVA / 10 kV unit: 1970 × 1420 × 1850 mm overall, 4,050 kg total weight with oil

Other voltages, dual-secondaries and units built to a non-standard impedance are made to order. A 22 kV 2 MVA oil-immersed unit with published dimensions and weight is a useful reference point if you are working out clearances.

Oil-immersed, or cast resin?

Electrically, both types will do the job. What separates them is where you are allowed to put them.

Oil-immersed units (ONAN, ONAF) cost less per kVA, take up less floor space, tolerate sustained overload better in hot climates, and can be repaired on site by your own maintenance team. They also need bunding, oil containment and fire separation, which normally rules them out inside an occupied building or under a populated floor.

Cast-resin dry-type units have no oil, so no bunding and no fire-rated enclosure. F-class insulation with AN or AF cooling. They cost more, run louder in some designs, and are considerably less forgiving of repeated overload. Pick dry-type for indoor substations, data centres, tunnels, hospitals, and anywhere an oil spill is not an acceptable risk. The 2 MVA cast resin transformer we build in the same works is the version most often specified for those sites.

The parameters that decide whether the unit lasts

Impedance (%Z). Usually 4.5% to 6% at this rating. A lower figure cuts losses but raises the fault current at the LV busbar. Check that number against your breaker rating before you accept any quotation, including ours.

Losses. Every unit ships with a routine test report showing measured no-load and load loss. If your tender carries a loss capitalisation formula, send it over and we will quote the grade that wins on 25-year total cost rather than the cheapest unit on day one.

Temperature rise. Oil-immersed units are designed to 55 K / 60 K. Cast-resin units are sized to their insulation class. Site ambient above 40 °C, or an installation altitude above 1,000 m, needs correction under IEC 60076-2. Tell us at enquiry stage, not at commissioning.

Vector group. Dyn11 is the default for LV distribution. For a 33/11 kV step-down, expect YNd11 or YNyn0.

Tap range. ±2 × 2.5% off-circuit tapping is standard. Ask for an OLTC only if you genuinely need to regulate under load. It adds cost, oil volume and a maintenance item for the life of the unit.

Manufacturing and testing

Our site covers 33,300 m² with 260 employees and an annual capacity above 1,000 MVA. Eighteen engineers handle design and type-test work. Cores are step-lapped from cold-rolled grain-oriented silicon steel, and windings are copper, dried under vacuum before oil filling.

2MVA transformer production process winding casting drying testing
Winding, casting, vacuum drying and high-voltage testing, all in-house

Every 2MVA Transformer goes out with routine tests to IEC 60076-1: ratio and vector group, winding resistance, no-load loss and no-load current, impedance voltage and load loss, applied voltage and induced voltage. Lightning impulse and temperature-rise tests are available as type tests, with third-party witnessing if your contract requires it. ISO 9001:2015 covers the process, and CE, UL and RoHS documentation is issued on request.

2MVA transformer certificates ISO 9001 CE quality management
Quality management, CE conformity and product certification held by the works

Recent shipments include 30 × 200 kVA to Oman, 8 × 160 kVA to Laos, 5 × 100 kVA to Iran, and a custom 4,000 kVA 11/0.415 kV unit with side outgoing lines for a customer in South Africa. Different ratings, same process.

Custom built transformer with side outgoing lines for South Africa
Custom unit with side outgoing lines, built for a customer in South Africa

Packing, lead time, warranty

MOQ is one unit. Standard export packing is a seaworthy wooden crate with the transformer braced to the base plate. Pallets and rack frames are available if the site has a crane limit. Lead time is quoted per order: for a standard rating on an existing design it is measured in weeks, not months. Warranty is 24 months. OEM and ODM are available, including your nameplate, your drawing numbers and your test report format. Technical support runs 7×24, before the order as well as after it.

2MVA transformer export packing in seaworthy wooden case
Export packing: braced to the base, then closed in a seaworthy case

What to send for a firm quotation

Nine items and we can quote without another round of emails:

  1. Rated power (confirm 2,000 kVA) and number of phases
  2. Primary and secondary voltage, and whether the LV neutral is brought out
  3. Frequency: 50 Hz or 60 Hz
  4. Vector group
  5. Impedance, if your specification fixes it
  6. Loss limits, or your loss capitalisation formula
  7. Indoor or outdoor, and the clearances you have on site
  8. Site ambient temperature, altitude and seismic zone
  9. Applicable standard, and any third-party inspection requirement

FAQ

How much does a 2 MVA transformer weigh?
A 2 MVA, 22 kV / 415 V oil-immersed unit is around 4,050 kg with oil. Dry-type units are lighter, but the figure depends heavily on the voltage class. Final weight is confirmed on the approved outline drawing, so get that number before you pour the plinth.

2 MVA or 2.5 MVA - which should I order?
Our rule of thumb is to size for a continuous load of roughly 60% to 75% of nameplate, so a cooling fault or a single outage does not take the plant down. On a 2 MVA unit that works out at a peak demand near 1.2–1.5 MVA. If your peak already sits near the top of that band and you expect growth, a 2.5 MVA transformer usually works out cheaper than replacing the 2 MVA unit in three years.

Can you match a competitor's drawing?
Yes. Send the drawing or the competitor's model number and we will confirm interchangeability of mounting centres, terminal positions and overall dimensions before you place an order.

Do you issue test reports before shipping?
Yes. Routine test reports come from our own works. Third-party witness testing can be arranged through your nominated inspection body if the contract calls for it.

Get a priced offer

A 2MVA Transformer is sized to your fault level, your ambient and your load profile. Send us those three, even as rough numbers, and you will get a priced offer together with a preliminary outline drawing. If you are still weighing oil-immersed against dry-type, say so - we will tell you which one suits your site rather than which one is easier for us to build.

Baoding Zhongyi Electric Corporation · MOQ 1 unit · 24-month warranty · 7×24 technical support · Send your specification and we will come back with a price

Hot Tags: 2mva transformer, China, suppliers, manufacturers, factory, buy, price, for sale, 100kva 3 phase transformer, 200 kva transformer, 11kv 1000 kva transformer, 10 mva 33 11kv transformer, 300 kva oil filled transformer, distribution transformer 2000 kva