Products
2.5MVA Dry Type Transformer
Power Rating: 2.5 MVA
Voltage Rating: 10kV-35kV
Frequency: 50/60Hz
Cooling Method: Air
Efficiency: ≥ 98%
Features
Baoding Zhongyi Electric Corporation is one of the leading manufacturers and suppliers of 2.5mva dry type transformer in China, featured by quality products and good price. Please rest assured to buy advanced 2.5mva dry type transformer for sale here from our factory.
A 2.5 MVA dry type transformer stands between the medium-voltage switchgear and the load, in a room with no oil in it. That one fact drives most of the decisions on this page. We build these units to order in Baoding, China, for primaries from 10 kV up to 35 kV. Cast resin windings, air cooling, IEC and ANSI and GB design. Below is what we ask customers before quoting, and what we would flag if we were standing in your substation.
Where a 2.5 MVA unit tends to end up
Industrial plants buy it as the main transformer inside the building. Data centres use it where the incoming supply is medium voltage and the UPS sits downstream. Hospitals and airport terminals order it because the fire officer will not approve oil inside a plant room. Metro and tunnel projects mount it near the load rather than pulling long LV cable runs.
One case comes up again and again. A site is replacing an oil-immersed transformer that no longer satisfies its insurer. The load has not changed. The room does not have to change either, apart from ventilation. That is usually the whole business case.

Ratings we build to
| Parameter | Value |
|---|---|
| Rated power | 2.5 MVA (2500 kVA), three-phase |
| Primary voltage | 10 kV to 35 kV (10, 11, 20, 22, 33 or 35 kV class) |
| Secondary voltage | To specification, commonly 0.4 kV, 0.433 kV, 6.6 kV or 11 kV |
| Frequency | 50 / 60 Hz |
| Cooling | Air, natural (AN) as standard. Forced-air (AF) quoted as a second rating stage |
| Insulation system | Class F cast resin as standard, Class H available |
| Standards | IEC 60076-11, ANSI, GB |
| Efficiency | ≥98% at the design load point |
| Enclosure | Open unit indoors, or IP-rated enclosure and kiosk for outdoor and dusty sites |
The voltage class decides the winding
Pick the primary voltage and you have already picked part of the design. Higher class means thicker insulation, a larger air clearance and a heavier unit. Rated current follows the same rating in the opposite direction. At 2.5 MVA, three-phase:
| Primary voltage | Rated current |
|---|---|
| 10 kV | 144 A |
| 11 kV | 131 A |
| 20 kV | 72 A |
| 33 kV | 44 A |
| 35 kV | 41 A |
Those currents are what your cable, busbar and protection settings have to carry. The insulation levels below are the standard ones for the classes inside this range:
| Voltage class (Um) | Lightning impulse | Power-frequency withstand |
|---|---|---|
| 12 kV | 75 kV peak | 28 kV |
| 24 kV | 125 kV peak | 50 kV |
| 36 kV | 170 kV peak | 70 kV |
Currents above are calculated from the rating for planning. The nameplate and the guaranteed technical particulars issued with your order are what we are held to.

Send these and the quote comes back fast
Price moves with each item on this list, so it is worth half an hour of your time before you write the enquiry.
- Primary and secondary voltage, vector group, tap range. Off-circuit ±2 x 2.5% is common, on-load where the incoming voltage wanders.
- Insulation class. Class F is our standard cast resin system. Class H if the ambient is hot or the duty is severe.
- Cooling. AN alone, or AN with fans for a higher peak rating.
- Enclosure and IP rating, and whether the unit sits indoors, in a container kiosk, or outside.
- Impedance, if the transformer will run in parallel with anything already on site. It has to match.
- Sound limit in dB(A) when the room has an acoustic constraint.
- Harmonic load. Rectifiers, VFDs, UPS systems and IT load may need a derated or K-rated design. Ask early. This one changes the winding, so it cannot be fixed after the order.

Testing
Every unit is routine tested in our works. The set covers winding resistance, voltage ratio and vector group, no-load loss and current, load loss and impedance, insulation resistance, and applied plus induced overvoltage tests. Partial discharge is measured as part of the dielectric routine, to an acceptance level of below 10 pC at the test voltage set by the standard your project is written to. Sound level is measured on the unit itself, not calculated from a table. Lightning impulse and temperature rise are type tests on the design, with reports available for your project file.
Most buyers at this rating want to watch the tests. That is fine. Third-party inspectors are welcome. Tell us at order stage and it goes into the production programme; tell us at the end and we will be fitting your schedule around ours.

Certificates
The same transformer is documented differently depending on where it is going. CE declaration for Europe. UL where the project is written to North American practice. CCC for China. ISO 9001 quality documentation in every case. Rather than listing marks that may not apply, tell us the destination country and the standard your project cites, and we will confirm in writing what we can supply. With the unit you get the routine test report, approval and final drawings, nameplate data, an operation and maintenance manual, and the packing list.

Plan the room, not just the transformer
Cast resin needs air. A unit that cannot breathe will run hot whatever the nameplate says, and this is the mistake we see most often on site. Give the enclosure a clear air path. Leave room to inspect the windings and to replace the same frame later. Bring the cable or busbar to the terminals without pulling forces on the bushings.
Outdoors or in a kiosk, order the IP-rated enclosure with ventilation sized for the losses. A 2.5 MVA dry type transformer travels on a flat rack or in a crate, braced against transport loads, accessories in separate boxes. Lifting and jacking instructions ship with the packing list, and inspection before shipment can be arranged if your contract asks for it.

Questions we get at this rating
Which voltage classes can a 2.5 MVA dry type transformer be built for?
Primaries from 10 kV to 35 kV, so 10, 11, 20, 22, 33 and 35 kV classes in practice, each with the matching insulation level. Secondary windings follow your network, typically 0.4 kV, 0.433 kV, 6.6 kV or 11 kV.
Is air cooling enough, or do we need fans?
Natural air cooling covers the nameplate rating in a properly ventilated room. Fans add a second, higher continuous rating for peak or N-1 duty. Send the room dimensions and the ambient temperature and we will tell you which arrangement is honest for your case.
Can it replace an oil transformer in an existing substation?
Usually yes. Check three things. Room height and door opening, because the dry type unit is heavier. Ventilation, because losses are higher. Impedance, if it will run in parallel with an existing transformer. A room drawing and the old nameplate are enough for us to confirm the fit before we quote.
What about harmonics from UPS, VFD or data centre loads?
Send the harmonic spectrum, or just tell us what the load is. A derated or K-rated design may be the right answer rather than a standard unit.
What impedance and temperature rise will our unit have?
Both follow your system and your specification rather than a catalogue. Impedance is chosen for fault level and for parallel operation with whatever else is on the bus, while the temperature rise class follows from the insulation system and the duty you specify, which is why both figures belong on the guaranteed technical particulars rather than in a sales table. They are verified in the tests before the unit ships.
Can we witness the tests?
Yes, and we would rather you did.
Tell us the primary and secondary voltages, the vector group, the impedance you need and the room conditions. You will get the general arrangement drawing, the guaranteed technical particulars, and a delivery date you can actually plan the substation works around.