100kVA Pad Mounted Transformer 10kv 380V Dry Transformer

100kVA Pad Mounted Transformer 10kv 380V Dry Transformer

100kVA Pad Mounted Transformer 10kv 380V Dry Transformer

Type:Class F Dry type Transformer
MOQ:1pc
Warranty:1 year
OEM/ODM Service:Yes
Certification:ISO 9001
Shipping:Sea
Payment:T/T

Features

Since the source of improving cost effectiveness is design, we constantly optimize product design of our 2000 kva dry type transformer, 300kva dry type transformer, sgb dry type transformer to reduce costs and enhance benefit. Relying on complete testing equipment, perfect testing methods, and strict quality standards, we have been committed to improving the quality and performance of our products. Strengthen the sense of competition and build a team spirit. We uses the e-commerce system to strengthen and promote customer relationship management, customer business operation, customer service and information communication. Through continuous development, we have gradually formed the core values of integrity, synergy, innovation and excellence.

2-Years Warranty

Our Sales Manager Grace with 10-Years Transformer Export Experience


Products Description

Dry type cast resin transformer, as an indispensable part of the power system, its importance is self-evident. It not only plays a key role in power transmission and distribution, but also has a wide range of applications in industry, construction, transportation and other fields.


Application of Dry Type Transformer in Power System

As an indispensable part of the power system, the epoxy resin cast dry encapsulated transformer not only converts high-voltage power into low-voltage power, but also plays an important role in the stability of the power grid, power quality, power grid security and so on.

1. Improve power grid stability

Dry type transformer has high insulation grade and insulation strength, which can effectively prevent equipment failure and electrical failure. At the same time, its small size, light weight, occupying less area, has a positive role in promoting the stability and reliability of the power grid.

2. Improve power quality

The high efficiency and low loss of dry transformers can greatly improve power quality and reduce energy waste. At the same time, its oil-free design also avoids the influence of oil pollution on power quality, making the quality of power more stable and reliable.

3. Improve grid security

The dry transformer has high safety, and the oil-free design avoids the impact of oil leakage and oil pollution on the safety of the power grid. The insulation material of the dry transformer is not easy to age, which can ensure the safety and reliability of the equipment for long-term operation.


Application of Dry Type Transformers in Other Fields

In addition to its application in power systems, epoxy resin cast dry encapsulated transformers are also widely used in industry, construction, transportation and other fields.

1. In the industrial field, dry transformers can be used for the production of electroplating, welding, calcium carbide, etc., to improve production efficiency and product quality.

2. In the field of construction, dry transformers can be used to supply power to shopping malls, hospitals, hotels and other buildings to meet a large amount of electricity demand.

3. In the field of transportation, dry transformers can be used for power supply of railways, subways, airports and other places to improve the safety and stability of transportation facilities.


Products Advantage


Epoxy resin cast dry encapsulated transformer advantages is as below.

1. High security

Dry transformers use dry edge materials, unlike oil-immersed transformers, it does not require oil cooling, so there is no oil leakage and oil contamination. This oil-free design not only greatly improves the safety of the equipment, but also reduces the pollution to the environment and makes it more environmentally friendly.

2. Low maintenance cost

Because dry-type transformers do not require refueling, their maintenance costs are greatly reduced. Because the insulation material of the dry transformer is not easy to age, its life is longer than that of the oil-immersed transformer, which also saves the cost of maintenance and replacement of the equipment for the user.

3. Wide range of application

The dry transformer is small in size and light in weight, and is suitable for various occasions. For example, it can be used in basements, high-rise buildings, ships and other places where space is limited. Dry transformers can also be used in explosion-proof sites and strong electromagnetic interference environments.


Technical Parameter

 

 Technical Parameter for 6kV, 10kV& 30kVA-2500kVA With Off Circuit Dry Type Transformer

(KVA)Rated capacityVoltage CombinationConnection Group SymbolNo-load Loss(W)Load Loss (W)No-load Current (%)Short-circuit Impedance(%)
High Voltage (KV)Tapping ranges of High VoltageLow Voltage(KV)130℃(B) (100℃)155℃(F) (120℃)180℃(H) (145℃)
306
6.3
6.6
10
10.5
11
±2.5%
±5%
0.4Dyn11 Yyn019067071076024
50270940100010702
803701290138014801.5
1004001480157016901.5
1254701740185019801.3
1605402000213022801.3
200±2X2.5%
±5%
6202370253027101.1
2507202590276029601.1
3158803270347037301
4009803750399042801
50011504590488052301
63013405530588062900.85
63013005610596064000.856
80015206550696074600.85
100017707650813087600.85
1250209091009690103000.85
160024501100011700125000.85
200030501360014400155000.7
250036001610017100184000.7
16002450122012900139000.858
200030501500015900171000.7
250036001770018800202000.7


Technical Parameter for 20kV 50kVA-2500kVA With Off Circuit Dry Type Transformer

(KVA)Rated capacityVoltage CombinationConnection Group SymbolNo-load Loss(W)Load Loss (W)No-load Current (%)Short-circuit Impedance(%)
High Voltage (KV)Tapping ranges of High VoltageLow Voltage(KV)130℃(B) (100℃)155℃(F) (120℃)180℃(H) (145℃)
5020
22
24
±2.5%
±5%
0.4Dyn11 Yyn034011601230131025.0
1005401870199021301.8
1606702350247034601.8
200±2X2.5%
±5%
7302770294031401.8
2508403220342036601.8
3159703850408043601.8
40011504650484051801.1
50013505460579061901.1
63015306450684073201
80017507790826088401
1000207092209780104000.85
125023801080011500123000.85
160027901300013800148000.85
200032401540016300175000.78.0
250038701820019300207000.7
200032401680017800191000.7
250038702000021200227000.7


Technical Parameter for 35kV 50kVA-2500kVA With Off Circuit Dry Type Transformer

(KVA)Rated capacityVoltage CombinationConnection Group SymbolNo-load Loss(W)Load Loss (W)No-load Current (%)Short-circuit Impedance(%)
High Voltage (KV)Tapping ranges of High VoltageLow Voltage(KV)130℃(B) (100℃)155℃(F) (120℃)180℃(H) (145℃)
5035
36
37
38.5
±2.5%
±5%
0.4Dyn11 Yyn04501340142015202.36
1006301970209022302
1600.792650281030001.5
200±2X2.5%
±5%
0.883130332035501.5
2500.993580380040601.3
31511704250451048201.3
40013705100541057901.1
50015206270665071101.1
63018607250769082301
80021608600912097601
10002430986010400111000.75
125028301200012700136000.75
160032401460015400165000.75
200038201720018200195000.75
250044502060021800233000.75


If you are interested in our products, please contact us gracejia@zydqjt.com or SEND INQUIRY to us, we will reply you within one hour.


Packaging & Delivery

 

Generally, we will use wooden packing suitable for long distance transportation such as sea transportation.We can also customize special packaging according to customer requirements.

Dry type transformer packaging

Export Reference:

export reference

Cast Resin Transformer Structure

 

Iron Core:


The role of dry transformer core is to form a magnetic circuit, in order to reduce eddy current loss, the core is made of thin silicon steel sheet staggered. 


The surface of the silicon steel sheet is coated with insulating paint and oxidized to form an insulating layer. 


The core is mainly composed of an iron core body, fasteners and insulating parts.

dry type transformer.jpg

 

Winding:


The winding of the transformer is made of high strength enamelled wire. When winding, cylindrical winding is used, and the low-voltage winding is close to the core in order to insulate it from the core. The high voltage winding is concentric over the low voltage winding. According to the winding can be divided into three categories:

(1) Single-turn dry transformer has only one winding, also known as auto-dry transformer.

(2) The double-coil dry transformer has two windings.

(3) The multi-coil dry transformer has more than two windings, and the commonly used three-coil dry transformer.


epoxy resin transformer.jpg

 

Protection Enclosure:


The protection level of transformer protection case ranges from IP21 to IP54.



We have three types of enclosure for your options.

13.8kv dry type transformer.jpg

 

Production Process

 30

31

Why Choose Us

 

 

343536

If you are interested in our products, please contact us gracejia@zydqjt.com or SEND INQUIRY to us, we will reply you within one hour.

We have a group of professional and technical personnel who have been engaged in the production of 100kVA Pad Mounted Transformer 10kv 380V Dry Transformer for many years in the industry. We keep up with the pace of the times, aiming at the foreign trade market. We continue to improve the manufacturing process of our products by increasing technological innovation.

Hot Tags: class f epoxy resin cast dry encapsulated transformer, China, suppliers, manufacturers, factory, buy, price, for sale, 3150 kva transformer, 11kv to 1kv transformer, dry type transformer with oltc, 100 kva single phase pad mounted transformer, 250kva transformer, power station transformer

Previous:

No Information

You Might Also Like