Low Cost Factory Directly Sale Dry Cooler

Low Cost Factory Directly Sale Dry Cooler
Type:Class F Dry type Transformer
MOQ:1pc
Warranty:1 year
OEM/ODM Service:Yes
Certification:ISO 9001
Shipping:Sea
Payment:T/T
Features
2-Years Warranty
Our Sales Manager Grace with 10-Years Transformer Export Experience
Products Description
Dry type cast resin transformer, as an indispensable part of the power system, its importance is self-evident. It not only plays a key role in power transmission and distribution, but also has a wide range of applications in industry, construction, transportation and other fields.
Application of Dry Type Transformer in Power System
As an indispensable part of the power system, the epoxy resin cast dry encapsulated transformer not only converts high-voltage power into low-voltage power, but also plays an important role in the stability of the power grid, power quality, power grid security and so on.
1. Improve power grid stability
Dry type transformer has high insulation grade and insulation strength, which can effectively prevent equipment failure and electrical failure. At the same time, its small size, light weight, occupying less area, has a positive role in promoting the stability and reliability of the power grid.
2. Improve power quality
The high efficiency and low loss of dry transformers can greatly improve power quality and reduce energy waste. At the same time, its oil-free design also avoids the influence of oil pollution on power quality, making the quality of power more stable and reliable.
3. Improve grid security
The dry transformer has high safety, and the oil-free design avoids the impact of oil leakage and oil pollution on the safety of the power grid. The insulation material of the dry transformer is not easy to age, which can ensure the safety and reliability of the equipment for long-term operation.
Application of Dry Type Transformers in Other Fields
In addition to its application in power systems, epoxy resin cast dry encapsulated transformers are also widely used in industry, construction, transportation and other fields.
1. In the industrial field, dry transformers can be used for the production of electroplating, welding, calcium carbide, etc., to improve production efficiency and product quality.
2. In the field of construction, dry transformers can be used to supply power to shopping malls, hospitals, hotels and other buildings to meet a large amount of electricity demand.
3. In the field of transportation, dry transformers can be used for power supply of railways, subways, airports and other places to improve the safety and stability of transportation facilities.
Products Advantage
Epoxy resin cast dry encapsulated transformer advantages is as below.
1. High security
Dry transformers use dry edge materials, unlike oil-immersed transformers, it does not require oil cooling, so there is no oil leakage and oil contamination. This oil-free design not only greatly improves the safety of the equipment, but also reduces the pollution to the environment and makes it more environmentally friendly.
2. Low maintenance cost
Because dry-type transformers do not require refueling, their maintenance costs are greatly reduced. Because the insulation material of the dry transformer is not easy to age, its life is longer than that of the oil-immersed transformer, which also saves the cost of maintenance and replacement of the equipment for the user.
3. Wide range of application
The dry transformer is small in size and light in weight, and is suitable for various occasions. For example, it can be used in basements, high-rise buildings, ships and other places where space is limited. Dry transformers can also be used in explosion-proof sites and strong electromagnetic interference environments.
Technical Parameter
Technical Parameter for 6kV, 10kV& 30kVA-2500kVA With Off Circuit Dry Type Transformer
| (KVA)Rated capacity | Voltage Combination | Connection Group Symbol | No-load Loss(W) | Load Loss (W) | No-load Current (%) | Short-circuit Impedance(%) | ||||
| High Voltage (KV) | Tapping ranges of High Voltage | Low Voltage(KV) | 130℃(B) (100℃) | 155℃(F) (120℃) | 180℃(H) (145℃) | |||||
| 30 | 6 6.3 6.6 10 10.5 11 | ±2.5% ±5% | 0.4 | Dyn11 Yyn0 | 190 | 670 | 710 | 760 | 2 | 4 |
| 50 | 270 | 940 | 1000 | 1070 | 2 | |||||
| 80 | 370 | 1290 | 1380 | 1480 | 1.5 | |||||
| 100 | 400 | 1480 | 1570 | 1690 | 1.5 | |||||
| 125 | 470 | 1740 | 1850 | 1980 | 1.3 | |||||
| 160 | 540 | 2000 | 2130 | 2280 | 1.3 | |||||
| 200 | ±2X2.5% ±5% | 620 | 2370 | 2530 | 2710 | 1.1 | ||||
| 250 | 720 | 2590 | 2760 | 2960 | 1.1 | |||||
| 315 | 880 | 3270 | 3470 | 3730 | 1 | |||||
| 400 | 980 | 3750 | 3990 | 4280 | 1 | |||||
| 500 | 1150 | 4590 | 4880 | 5230 | 1 | |||||
| 630 | 1340 | 5530 | 5880 | 6290 | 0.85 | |||||
| 630 | 1300 | 5610 | 5960 | 6400 | 0.85 | 6 | ||||
| 800 | 1520 | 6550 | 6960 | 7460 | 0.85 | |||||
| 1000 | 1770 | 7650 | 8130 | 8760 | 0.85 | |||||
| 1250 | 2090 | 9100 | 9690 | 10300 | 0.85 | |||||
| 1600 | 2450 | 11000 | 11700 | 12500 | 0.85 | |||||
| 2000 | 3050 | 13600 | 14400 | 15500 | 0.7 | |||||
| 2500 | 3600 | 16100 | 17100 | 18400 | 0.7 | |||||
| 1600 | 2450 | 1220 | 12900 | 13900 | 0.85 | 8 | ||||
| 2000 | 3050 | 15000 | 15900 | 17100 | 0.7 | |||||
| 2500 | 3600 | 17700 | 18800 | 20200 | 0.7 | |||||
Technical Parameter for 20kV 50kVA-2500kVA With Off Circuit Dry Type Transformer
| (KVA)Rated capacity | Voltage Combination | Connection Group Symbol | No-load Loss(W) | Load Loss (W) | No-load Current (%) | Short-circuit Impedance(%) | ||||
| High Voltage (KV) | Tapping ranges of High Voltage | Low Voltage(KV) | 130℃(B) (100℃) | 155℃(F) (120℃) | 180℃(H) (145℃) | |||||
| 50 | 20 22 24 | ±2.5% ±5% | 0.4 | Dyn11 Yyn0 | 340 | 1160 | 1230 | 1310 | 2 | 5.0 |
| 100 | 540 | 1870 | 1990 | 2130 | 1.8 | |||||
| 160 | 670 | 2350 | 2470 | 3460 | 1.8 | |||||
| 200 | ±2X2.5% ±5% | 730 | 2770 | 2940 | 3140 | 1.8 | ||||
| 250 | 840 | 3220 | 3420 | 3660 | 1.8 | |||||
| 315 | 970 | 3850 | 4080 | 4360 | 1.8 | |||||
| 400 | 1150 | 4650 | 4840 | 5180 | 1.1 | |||||
| 500 | 1350 | 5460 | 5790 | 6190 | 1.1 | |||||
| 630 | 1530 | 6450 | 6840 | 7320 | 1 | |||||
| 800 | 1750 | 7790 | 8260 | 8840 | 1 | |||||
| 1000 | 2070 | 9220 | 9780 | 10400 | 0.85 | |||||
| 1250 | 2380 | 10800 | 11500 | 12300 | 0.85 | |||||
| 1600 | 2790 | 13000 | 13800 | 14800 | 0.85 | |||||
| 2000 | 3240 | 15400 | 16300 | 17500 | 0.7 | 8.0 | ||||
| 2500 | 3870 | 18200 | 19300 | 20700 | 0.7 | |||||
| 2000 | 3240 | 16800 | 17800 | 19100 | 0.7 | |||||
| 2500 | 3870 | 20000 | 21200 | 22700 | 0.7 | |||||
Technical Parameter for 35kV 50kVA-2500kVA With Off Circuit Dry Type Transformer
| (KVA)Rated capacity | Voltage Combination | Connection Group Symbol | No-load Loss(W) | Load Loss (W) | No-load Current (%) | Short-circuit Impedance(%) | ||||
| High Voltage (KV) | Tapping ranges of High Voltage | Low Voltage(KV) | 130℃(B) (100℃) | 155℃(F) (120℃) | 180℃(H) (145℃) | |||||
| 50 | 35 36 37 38.5 | ±2.5% ±5% | 0.4 | Dyn11 Yyn0 | 450 | 1340 | 1420 | 1520 | 2.3 | 6 |
| 100 | 630 | 1970 | 2090 | 2230 | 2 | |||||
| 160 | 0.79 | 2650 | 2810 | 3000 | 1.5 | |||||
| 200 | ±2X2.5% ±5% | 0.88 | 3130 | 3320 | 3550 | 1.5 | ||||
| 250 | 0.99 | 3580 | 3800 | 4060 | 1.3 | |||||
| 315 | 1170 | 4250 | 4510 | 4820 | 1.3 | |||||
| 400 | 1370 | 5100 | 5410 | 5790 | 1.1 | |||||
| 500 | 1520 | 6270 | 6650 | 7110 | 1.1 | |||||
| 630 | 1860 | 7250 | 7690 | 8230 | 1 | |||||
| 800 | 2160 | 8600 | 9120 | 9760 | 1 | |||||
| 1000 | 2430 | 9860 | 10400 | 11100 | 0.75 | |||||
| 1250 | 2830 | 12000 | 12700 | 13600 | 0.75 | |||||
| 1600 | 3240 | 14600 | 15400 | 16500 | 0.75 | |||||
| 2000 | 3820 | 17200 | 18200 | 19500 | 0.75 | |||||
| 2500 | 4450 | 20600 | 21800 | 23300 | 0.75 | |||||
If you are interested in our products, please contact us gracejia@zydqjt.com or SEND INQUIRY to us, we will reply you within one hour.
Packaging & Delivery
Generally, we will use wooden packing suitable for long distance transportation such as sea transportation.We can also customize special packaging according to customer requirements.

Export Reference:

Cast Resin Transformer Structure
Iron Core:
The role of dry transformer core is to form a magnetic circuit, in order to reduce eddy current loss, the core is made of thin silicon steel sheet staggered.
The surface of the silicon steel sheet is coated with insulating paint and oxidized to form an insulating layer.
The core is mainly composed of an iron core body, fasteners and insulating parts.

Winding:
The winding of the transformer is made of high strength enamelled wire. When winding, cylindrical winding is used, and the low-voltage winding is close to the core in order to insulate it from the core. The high voltage winding is concentric over the low voltage winding. According to the winding can be divided into three categories:
(1) Single-turn dry transformer has only one winding, also known as auto-dry transformer.
(2) The double-coil dry transformer has two windings.
(3) The multi-coil dry transformer has more than two windings, and the commonly used three-coil dry transformer.
Protection Enclosure:
The protection level of transformer protection case ranges from IP21 to IP54.
We have three types of enclosure for your options.
Production Process


Why Choose Us



If you are interested in our products, please contact us gracejia@zydqjt.com or SEND INQUIRY to us, we will reply you within one hour.
We create opportunities for horizontal exchanges in the Low Cost Factory Directly Sale Dry Cooler industry and introduce professional leaders externally to accelerate the pace of our development. Over the years, we have consciously fulfilled our social citizenship responsibilities and insisted on the harmonious development of society, economy and environment. Our operation begins with customer needs and ends with customer satisfaction, and we actively promote the humanization, standardization and normalization of quality service.Hot Tags: class f epoxy resin cast dry encapsulated transformer, China, suppliers, manufacturers, factory, buy, price, for sale, distribution transformer 11 0 4kv, high voltage oil transformer, dry resin transformer, 50 kva overhead transformer, 2500 kva pad mounted transformer, 11kv to 1kv transformer
No Information